  Datasheet File OCR Text:
 MPB125 SERIES
DESCRIPTION The MPB125 series incorporates patented high efficiency circuitry, high power density and active Power Factor Correction (PFC) to meet the requirements of networking and data communications systems, as well as commercial and industrial configurations. Dual output units deliver a regulated main output plus a second 12V output for fans or other system functions. Multiple output models provide tightly regulated DC power in a variety of configurations. The MPB125 is rated for convection as well as forced-air cooling. Full FEATURES * * * * * * High Power Density in Industry Standard 3" x 5" Footprint Power Factor Correction (PFC) Meets EN61000-3-2 Main Output Remote Sense Power Good Signals CE Marked to Low Voltage Directive Input Transient & ESD Compliance to EN61000-4-2/-3/-4/-5
80 Watts Convection Cooling, 125 Watts Forced-Air Cooling
MODEL OUTPUT VOLTAGE (VOLTS) MAXIMUM OUTPUT CURRENT (AMPS), 130 LFM (NOTE 2) TOTAL REGULATION %
Advanced Produc t Release
output power is available with as few as 130 Linear Feet per Minute (LFM) forced-air cooling. The MPB125 product line is approved to the latest international regulatory standards, and displays the CE Mark.
MULTIPLE OUTPUT MODEL SELECTION CHART RIPPLE & NOISE % pk-pk (NOTE 3) REGULATION RANGE
+5V 25A 3% +12V 0.5A 5% +12V 10.5A 3% MPB125-2012 +12V 0.5A 5% +15V 8.3A 3% MPB125-2015 +12V 0.5A 5% +24V 5.2A 3% MPB125-2024 +12V 0.5A 5% +48V 2.6A 3% MPB125-2048 +12V 0.5A 5% +5V 15A 3% MPB125-3000 +12V 5A 5% -12V 0.5A 3% +2.5V 10A (NOTE 4,5) 3% +5V 15A (NOTE 4,5) 3% MPB125-4250 +12V 5A 5% (NOTE 1) -12V 0.5A 3% +3.3V 10A (NOTE 4,5) 3% +5V 15A (NOTE 4,5) 3% MPB125-4350 +12V 5A 5% (NOTE 1) -12V 0.5A 3% NOTES: 1) Maximum convection output power is 75 watts. 2) Maximum forced-air output power is 125 watts with 130 LFM at 5 CFM. 3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 4) Maximum power of 80 watts from V1 + V2 with 130 LFM at 5 CFM forced-air cooling. 5) Maximum power of 45 watts from V1 + V2 for convection cooling. MPB125-2005
1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1%
4.85V to 5.15V 11.40V to 12.60V 11.64V to 12.36V 11.40V to 12.60V 14.54V to 15.45V 11.40V to 12.60V 23.28V to 24.72V 11.40V to 12.60V 46.56V to 49.44V 11.40V to 12.60V 4.85V to 5.15V 11.40V to 12.60V -11.64V to -12.36V 2.42V to 2.58V 4.85V to 5.15V 11.40V to 12.60V -11.64V to -12.36V 3.20V to 3.40V 4.85V to 5.15V 11.40V to 12.60V -11.64V to -12.36V
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
REV. 08/23/01
1
MPB125 SERIES
INPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION
Advanced Produc t Release
MIN NOM MAX UNITS
Input Voltage- AC Input Frequency Brownout Protection Hold-up Time Input Current Input Protection Inrush Surge Current Power Factor Circuitry Operating Frequency
Continuous input range. AC Input. Lowest AC input voltage that regulation is maintained with full rated loads. Over full AC input voltage range at full rated load. 90 VAC at full rated load. Non-user serviceable internally located AC input line fuse, 3.15A. Internally limited by thermistor, 110VAC: one cycle, 25 C. 220VAC: Active PFC meets requirements of EN61000-3-2. Switching frequency of main transformer.
90 47 90 17
264 63
1.8 23 46 100
VAC Hz VAC mS ARMS APK kHz
OUTPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Efficiency Minimum Loads Ripple and Noise Output Power
Overshoot /Undershoot Regulation Transient Response Turn-on Delay Turn-on Rise Time
Full Load, 230VAC. Varies with distribution of loads among outputs. V1 + V2 + V3. Full load, 20 MHz bandwidth. 130 LFM at 5 CFM forced-air cooling. Convection, dual and triple-output models. Convection, four-output models. Output voltage overshoot/undershoot at turn-on. Varies by output. Total regulation includes: line changes from 85-132 VAC or 170-264 VAC, changes in load starting at 20% load and changing to 100% load. Maximum deviation due to a 25% load change with unit at 75% load. Time required for initial output voltage stabilization. Time required for output voltage to rise from 10% to 90%.
75 85 5 See Model Selection Chart 125 80 75 10 See Model Selection Chart 3 0.2 0.2 1.5 20
% Watts
Watts %
% Sec mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Overvoltage Protection
Overload Protection Remote Sense (Note 1) Power Good, Delay High Power Good, AC Fail
V1 of dual and triple output models; V1 & V2 outputs of 4-output models. MPB125-4250 (V1) MPB125-4350 (V1) MPB125-2005, MPB125-3000, MPB125-4X50 MPB125-2012 MPB125-2015 MPB125-2024 MPB125-2048 Fully protected against output short circuit. Automatic recovery upon removal of overload condition. Total voltage compensation for cable losses on +Sense. Total voltage compensation for cable losses on -Sense. TTL compatible signal is high if output is within 97% of nominal. Delay after outputs have reached 97%.
3.20 3.67 5.74 13.5 17.0 27.0 50.0
4.0 4.8 7.0 15.5 19.0 30.7 70.0
VDC
100 1.0
200 100 500
mV mS mS
TTL compatible signal is low if AC power is interrupted for 16 mS. Power warning before outputs reach 97% of nominal. NOTES: 1) -Sense must be connected to output common or load common for proper power supply operation.
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Agency Approvals
Dielectric Withstand Voltage Electromagnetic Interference
UL1950. CSA 22.2 No. 234/950. EN60950 (TUV). AC to chassis. Input to output. EN55022 Conducted.
Approved 1500 3000 B VAC VDC Class
2
MPB125 SERIES
SAFETY, REGULATORY, AND EMI SPECIFICATIONS (CONTINUED)
PARAMETER CONDITIONS/DESCRIPTION
Advanced Produc t Release
MIN NOM MAX UNITS
Flicker Radiated Susceptibility EFT/Burst Input Transient Protection RF Immunity Magnetic Fields Voltage Dips Insulation Resistance Leakage Current
Per EN61000-3-3. Per EN61000-4-3. Per EN61000-4-4. Per EN61000-4-5. Per EN61000-4-6. Per EN61000-4-8. Per EN61000-4-11. Input to output. Per EN60950 (264 VAC)
10 1.0
M mA
ENVIRONMENTAL SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Altitude Operating Temperature Storage Temperature Forced-Air Cooling
Operating Non-Operating At 100% load: Forced-air cooling of 130 LFM at 5 CFM is required for full output power. Air velocity is measured with power supply mounted on 0.375" (9.5mm) standoffs. Airflow direction is from the input section to the output section. 0C to 70C (after 15 minute warm-up). Non-Condensing. Operating: 11 3mS, 3 axes, Half Sine. Non-operating: 11 3mS, 3 axes, Half Sine. Operating: Random vibration, 5-500 Hz, 10 minutes each axis. Non-Operating: Random vibration, 5-500 Hz, 10 minutes each axis. 0 -40
10K 50K 50 70
ASL Feet C C
Temperature Coefficient Relative Humidity Shock Vibration
0.02 5
0.05 85 15 30 2.4 4.8
%/C %RH G GRMS GRMS
3
MPB125 SERIES
Advanced Produc t Release
J1 - AC I/P CONN. Pin 1 Pin 2 Pin 3 O 0.16" (4 PL) (4.06) J2 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pin 11 Pin 12 Pin 13 Pin 14 J3 NEUTRAL NO PIN LINE MPB125 -3000 -12V +12V N/C N/C N/C RTN RTN RTN RTN RTN +5V +5V +5V +5V MPB125 -4250 -12V +12V +2.5V +2.5V +2.5V RTN RTN RTN RTN RTN +5V +5V +5V +5V MPB125 -4350 -12V +12V +3.3V +3.3V +3.3V RTN RTN RTN RTN RTN +5V +5V +5V +5V
5.00" (127.0) 4.55" (115.57)
J1- INPUT CONNECTOR 2.56" (65.02) 3.00" (76.2) PIN #1
TOP VIEW
J2 - DC OUTPUT CONNECTOR
PIN #1
MPB125-3000 MPB125-4250 MPB125-4350
FASTENER CLEARANCE AREA (4 PL)
SAFETY GROUND CONNECTION POINT
SCREWS SHOWN FOR REFERENCE ONLY
J3
PIN #1
0.06" (1.5)
Pin 1 Pin 2 Pin 3
-SENSE +SENSE PWR GOOD
1.25" (31.75)
1.00" (25.4)
SIDE VIEW
PRINTED CIRCUIT BOARD
END VIEW
0.19" (4.8)
MPB125-2005
J2 - DC OUTPUT CONNECTOR PIN #1 PIN #1 J3
J2 - DC OUTPUT CONNECTOR PIN #1
J2 - DC OUTPUT CONNECTOR PIN #1
J2 - DC OUTPUT CONNECTOR PIN #1
MPB125-2012 MPB125-2015
PIN #1 J3
MPB125-2024
PIN #1 J3
MPB125-2048
PIN #1 J3
MATING CONNECTORS
NOTE: PART NUMBERS ARE MOLEX; EQUIVALENTS ARE ACCEPTABLE. MPB125 -2005 MPB125 -2012 -2015 09-50-8033 08-52-0113 09-50-8063 08-52-0113 22-01-3067 08-50-0114 MPB125 -2012 -2015 09-50-8033 08-52-0113 09-50-8063 08-52-0113 22-01-3067 08-50-0114 MPB125 -2024 MPB125 -2048 MPB125 -3000 -4250 -4350 09-50-8033 08-52-0113 09-50-8143 08-52-0113 22-01-3037 08-50-0114
J1 J2 J3
Housing Pins Housing Pins Housing Pins
09-50-8033 08-52-0113 09-50-8103 08-52-0113 22-01-3067 08-50-0114
09-50-8033 08-52-0113 09-50-8043 08-52-0113 22-01-3067 08-50-0114
09-50-8033 08-52-0113 09-50-8023 08-52-0113 22-01-3067 08-50-0114
4


▲Up To Search▲   

 
Price & Availability of MPB125-4350

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X